GE Marquette Mac PC Interpretive EKG ECG Machine SystemEXCELLENT CONDITION Machine!
90-Day Warranty
Here is what you get:
Marquette MAC PC EKG Machine
This unit has been cleaned, tested, inspected, reconditioned as needed. This EKG is sold without a cart. Very portable unit. Perfect for desktop/tabletop use.
This is an EXCELLENT CHOICE for a used WARRANTYd EKG Machine!
Marquette
Mac PC EKG tests
Advanced Computerized Personal Cardiograph
MAC PC Your key to complete EKG diagnostic services
You could use the MAC PC as a conventional office electrocardiograph.
It meets all the requirements: small, inexpensive, reliable and easy to
operate. But you wouldn't be using it to its--or your--full potential. Despite
its size and price, the MAC PC packs all the power of the most advanced
computerized hospital electrocardiograph. In just 15 seconds, it acquires
signals from 12 leads simultaneously and analyzes them with Marquette's
powerful--and accurate--12SL interpretive program. Perhaps even more important,
the MAC PC enables you to link up, via standard telephone line, with outside
cardiologists to offer more comprehensive EKG services from your office.
For example, a phone link to a hospital cardiology department or
cardiology group practice would enable you to obtain quick confirmation of your
diagnoses. With a modem-equipped MAC PC, you simply transmit such EKGs to a
cardiologist's Marquette electrocardiograph or MUSE EKG processing and
management system. You will receive back, on your MAC PC, the overread report.
Similarly, with the MAC PC you can receive Holter reports from a
Marquette Laser Holter system in minutes--a fraction of the time required to
receive the reports by mail or courier
In short, the MAC PC enables you to offer extensive EKG diagnostic
services with minimal investment. Even if you have no immediate interest in
offering such EKG services now, the MAC PC is a good investment because its
flexibility broadens your future options. Its phone-line transmission, or
"networking" capabilities can be added at any time.
The MAC PC is an advanced office-sized electrocardiograph. But it
is also much more than that. It is your key to expanding EKG diagnostic
services.
MAC PC High technology in a small,
inexpensive portable
We've coupled the latest computer microminiaturization technology
with our proven EKG analysis program to create a new health care product: a
truly portable personal cardiographic computer. Weighing only 11 pounds, the
size of a medical textbook, the MAC PC performs analyses that once required a
whole roomful of electronic equipment.
The MAC PC makes computer-analyzed EKGs available anywhere,
bringing state-of-the-art EKG capability to a variety of healthcare
settings--physicians' offices, clinics, ambulatory care centers, surgical
centers and even patients' homes. Never before has such electrocardiographic
power been available in an inexpensive, portable unit.
Acquiring the signals:
The MAC PC acquires
all 12 classical EKG leads simultaneously with Marquette's New Acquisition
Module, which, attached directly to the patient, digitizes the EKG waveforms
and sends the data to the unit via a standard, inexpensive telephone type
cable. This method of acquisition sets a new standard for signal quality.
Marquette 12SL analysis:
In 15 seconds, the MAC PC performs a complete 12-lead analysis of any EKG. The
analysis is based on the same proven 12SL program once available only with
room-sized EKG systems. The program contains age-specific criteria and
accurately analyzes EKGs from patients of all ages, from newborns to adults.
Continually fine-tuned by 28 of the world's leading electrocardiographers, the
12SL program processes nearly one in every four EKGs taken in the U.S. today.
it is backed by a still-growing data base of over 5 million EKGs and has earned
the trust of thousands of cardiologists worldwide.
Direct Digital Writer:
The MAC PC writes
both reports and waveforms with Marquette's solid-state Direct Digital Writer
Except for the paper drive, this writer has no pens or other moving parts. The
result is extremely reliable performance--no ink to run out, no pens to burn
out, nothing to go out of adjustment--and distortion-free waveforms. Waveforms
may be written in three- or six-channel formats.
Easy to use:
But despite its
power, the MAC PC is extremely easy to use. Just connect the electrodes and
push one button. The instrument does the rest. it collects 10 seconds of EKG
data from all 12 standard leads, performs a full analysis of morphology and
rhythm using Marquette's 12SL analysis program, and prints a report in the
format of your choice. The report includes heart rate, PR interval, QRS
duration, P-R-T axis measurement, QT and corrected QT. In addition, the
MAC PC will store up to 20 EKGs in solid state memory.
Networking with the
MAC
PC:
Equipped with a
modem, the MAC PC can communicate with thousands of other Marquette
electrocardiographs and EKG processing systems throughout the U.S. and in many
other countries. This networking capability enables you to transmit EKGs to
another Marquette electrocardiograph for overreading or to a MUSE system for
overreading, serial comparison, or storage. Because the MAC PC is battery
operated, you can take the unit anywhere--even to a patient's home--and
transmit ECGs via standard or cellular phones for quick overreading or a second
opinion. You can send EKGs from almost anywhere, even from patients' homes for
quick overreading or a second opinion. You can even take the MAC PC home with
you for receiving and overreading EKGs.
The optional modem also equips the MAC PC
to receive Holter
reports from Marquette Holter systems. The Holter report includes summary
statistics, interpretation and 10-second rhythm strips.
The specially built 2400 baud modem can be added at any time, so
even if you have no need to transmit and receive EKG information today, the MAC
PC assures you of that capability in the future.
Wherever you use it, the MAC PC can make you part of the growing
Marquette ECG communications network.
Analog Output Flexibility:
The MAC PC offers
additional flexibility with an Analog Output option. This feature enables you
to continuously monitor as many as three leads of EKG data on an oscilloscope.
During monitoring you may recall and printout 5 seconds of the three displayed
leads or 2.5 seconds of all 12 leads at operator programmable intervals or on |