More images:
Image for illustration only.
Actual item may not be pictured.
Larsen & Toubro Star 50 Patient Monitor - New
Display
Type : High Resolution Colour TFT
size : 10.4" (diagonally)
Resolution : 640 x 480 dots
Excellent viewing from distance and angle.
Waveform field : Configurable screen for max. four waveforms
(ECG, SpO 2, Resp, Invasive BP or CO2). Possible to view any 4 ECG leads, if 5 -lead ECG cable is connected (5 -lead version)
Digital field : HR/PR, ST, RR, SpO 2, T1, T2 or ΔT, IBP1, IBP2 & NIBP (Sys., Dia., MN), EtCO2 and FiCO2. On screen display of alarm limits/status.
Trace speed : 12.5, 25 or 50 mm/sec for ECG,
Invasive pressure waveforms and Plethysmograph.
6.25, 12.5 or 25 mm/sec for Respiration & CO 2.
Optical Encoder / Keys
Optical encoder : Rapid access to all the functions and setting of parameters through single knob.
Hot keys : Quick action hard keys for Alarm mute, NIBP Start / stop, IBP Zero, Freeze and Return to the main screen.
3/5 lead ECG monitoring
Automatic detection of 3 or 5 lead ECG cable. Display of I, II, III with 3-lead cable and I, II, III, aVR, aVL, aVF and V with 5-lead cable.
In-built cautery and defibrillator protection.
HR range : 20 to 270 bpm.
Programmable arrhythmia detection (Bradycardia, Tachycardia, Asystole, Irregular & Skipped beat)
Respiration
Impedance pneumography principle.
Display of respiration waveform with respiration rate.
Respiration range : 4 to 150 bpm
User selectable aponea alarm delay : 5 – 90sec. (steps of 5 sec.)
Temperature
Simultaneous monitoring of two temperatures. Display of T1 and T2 or T (if difference between T1 & T2 is less than 9.90C)
Temperature range: 12 0C to 430C
Pulse Oximetry
Pitch variation with change in oxygen saturation.
SpO 2 range: 0 - 100%
Display of pulse strength, plethysmograph and SpO 2 values.
Accuracy : 100 to 70 % (+/- 2 digits), 69 to 50 % (+/- 3 digits), 49 to 0 % (unspecified)
Accuracy in neonatal monitoring 100 to 70% (+/- 3 digits)
Invasive Blood Pressure
Simultaneous monitoring of 2 channels.
Display of Systolic, Diastolic and Mean pressure with respective waveform of IBP1 and IBP2. Individual and common channel zeroing.
Labeling facility with automatic limits/gain/colour setting.
Pressure channel overlapping option available.
Range : -40 to 300mmHg.
IBP scale : 300, 150, 60, 30, 20 & 10mmHg,
Non-Invasive Blood Pressure
Oscillometric Principle, Display of Systolic, Diastolic & Mean pressure
Modes : Manual, STAT (5min), Automatic (interval 2 min. to 90 min.)
Range : 20 to 255mmHg.
Accuracy : +/-5 mmHg
Capnography (Optional)
Side stream Capnography with display of CO 2 waveform and digital values of EtCO2 and FiCO2.
CO 2 gets priority for calculating Respiration rate.
Gain 20 ,40, 60 & 80 mmHg. Flow rate : 140 ml/min.(+20 / -10)
CO 2 measurement is possible in mmHg / Kpa / Vol%
EtCO 2 range : 0 – 80 mmHg, FiCO2 range : 2 – 20 mmHg
RR Range 0 - 150
Aponea alarm delay : 30 sec.
Alarms
Alarm setting for all parameters.
Patient alarm : RED flashing with audio and message indicator
Equipment alarm : YELLOW flashing with audio and message indicator. Alarm auto-set facility provided.
Alarm suspend : Continuous YELLOW
Auto setting of alarm for HR/PR, SpO 2, IBP1, IBP2, EtCO2, FiCO2,
Respiration and Temperature.
Re-alarm facility : 3 min. for acknowledged alarm
Trends
24 hr. of Graphical and Tabular trend for HR/PR, SpO 2, IBP1, IBP2, EtCO2, FiCO2, Respiration & Temperature.
NIBP trend : 240 readings tabular
Alarm Recall : Last 16 alarm events with date, time and message.
2hr. zoom for graphical trends with mark, record and print facility.
Recording (Optional)
Optional external dual channel thermal recorder for recording two waveforms (selectable) with numerical data and alarm status.
NIBP and tabular trend recording with patient information.
Direct / Delayed / Continuous modes of recording.
Record On Alarm facility (selectable)
General
Dimension : 202 x 310 x 230 mm (H x W x D)
Weight : 7.5 Kg. with in-built batteries.
Direct interface possible with Skyline - L&T’s colour central station.
Slave display option possible
Power Supply
Universal power : 95-265V AC, 50/60Hz
Power ratings : 40W
Battery type : 12V 4Ah lead acid
Operating time : In-built rechargeable batteries for 30min. of continuous operation under full charge condition (fully loaded, NIBP 2min. & recorder ON for 2min..)
Charging time : 12 hrs. (typical) Ambulatory monitoring possible with car battery interface
External battery : 12 V 2A(min)
|
Why Shop?
- 100% Secure Ordering
- Verisign Secure Server
- We Value Your Privacy
- No Hassle Return Policy
- Great Customer Service
Customer Satisfaction:
- Honesty, integrity, persistent with service...wholehearted recommendation petehillnp– Los Angeles, CA
- Excellent product & service. Will definitely do business with Absolute Medical again, countmonk– Chicago, IL
- Honesty, integrity, persistent with service...wholehearted recommendation petehillnp– Miami, FL
- Excellent product & service. Will definitely do business with Absolute Medical again, countmonk– Houston, TX
|
|
|
|